Reverse6-50R for only $366.02 - Steambrite's price on the Electrical Adapter Temporary Power Boxes - Reverse6-50R extractor, Equipmentcarpet cleaning equipment, Equipment flood restoration, Equipment carpet cleaning machine,

Steam-brite.com Click here for Steam-brite.com's Norton Safe Web Security Report
 

  Steam-brite » » Parts & Accessories » Electrical Adapter Temporary Power Boxes » Reverse6-50R My Account  |  Cart Contents  |  Checkout   

Store
Auto Detailing & Car Wash:
Chemicals
Construction Equipment
Equipment: Air Duct Cleaning Machines
Equipment: Carpet Cleaning Machines
Equipment: Hard Surface Cleaning Supplies
Equipment: Restoration
Escalator Cleaning Machines & Equipment
Generators Electrical
Janitorial Supplies Sanitorial
Miscellaneous
Parts & Accessories
   Bags, Belts & Magnets
   Battery Chargers And Batteries
   Blowers and Vacuum Pumps
   Bottles
   Brass, Plastic, Steel, Stainless Hydraulic Fittings
   Brushes, Bonnets, Pad Drivers, & Clutches
   Buckets
   Carpet Installation And Repair Tools
   Containment & Barrier Products
   DI and Reverse Osmosis Water Treatment Filters
   Drive, Lift, and Brush Motors
   Electric Car Chargers
   Electrical Adapter Temporary Power Boxes
   Electrical Components
   Engines
   Exhaust, Muffler, Silencer Systems
   Extension Power Cords
   Filters
   Fuel Tap Kits
   Gaskets, Lid, and Tops
   Gauges
   Glides
   Heaters
   Hose Clamps Metal
   Hose Cuffs & Connectors
   Hose Reels
   Hoses
   Husqvarna Accessories & Spare Parts
   Jets Nozzles TeeJets VeeJets Cone Spray M-Style Rotary Lazer
   Jetter Accessories
   Karcher Repair Parts
   Legend Brand Repair Parts
   Meters and Lights
   Miscellaneous Repair Parts
   Oil Change Extractor
   Ozone Cleaning Kits
   Pumps (Water Pumps)
   Quick Disconnects And Couplers
   Regulators & Unloaders
   Spray Bar Rotary Arms
   Sprayer
   Sprayer Parts
   Squeegee Blades
   Steel Wool
   Switches
   Swivels Pressure Rotary Union
   Tanks: Fuel, Water, Vacuum
   Trigger Sprayers
   US Products Treadmaster Accessories
   Vacuum Boosters
   Vacuum Motors
   Valves
   Van Accessories/Holders
   Vectorfog
   Wheels and Casters
   White Magic Parts
Schools, Training, Books, & Videos
Trailers And Farm
Welding Equipment
Window Cleaning Tools & Equipment
Business Start Up Kits
Used Items
Browse by Manufacturer
Steambrite
About Us
Privacy Notice
Conditions of Use
Contact Us
Sitemap
Shipping & Returns
Reviews Carpet Cleaning Equipment
Write ReviewWrite a review on this product!
Translate
English
French French
Spanish Spanish
German German
Italian Italian
Portuguese Portuguese

Clean Storm Reverse6-50R Power Joiner Step Up Inverter Dual 20 amp 120 volt outlets To 240 volt 3 wire 20amp 6-50R [Reverse6-50R]


Your Price:
Quantity1+2+ 4+ 8+ 
Price for each$366.02$354.62$347.92$344.65
Your savings- 3%5%6%

Part Number: Reverse6-50R
Quantity:
Estimated shipping cost: $ 18.00



Product Options
Accessories:
Add-ons:
Extended Warranty:
Shipping Surcharges:

Reviews


Clean Storm Reverse6-50R Power Joiner Step Up Inverter Converts Dual 20 amp 120 volt outlets To 240 volt 3 wire 20amp 6-50R

Description

step up 220 converter 6-50r receptacle Power Cord Adapter Inverter (Reverse Converter) Takes two 120 volt outlets and allows you to use 240 volt appliances that uses under 20 amp @ 240 volts (under 4800 watts) Single phase current to NEMA 6-50R receptacle.   Commonly used as an Welder plug.  Fast and easy 240 volts.

Other 220 to 240 volt receptacles available including but not limited to: NEMA 6-30R, NEMA 6-50R,
NEMA 10-30R, NEMA 14-30R, NEMA 14-50R, and many more



power converter systemNema 6-50R 240 volt electric car outlet
nema 3 wire configurations

nema 3 wire configurations

Perfect for electric cars, pressure washers, welders, plasma cutters, vapor steam cleaners, and other high powered equipment when 230 volt plugs are just not available.

Not for use on GFCI or LDCI 115/120 volt Outlets.

tesla and electric car charger converterTo use simply plug into different outlets and push the momentary button to test voltage.  If the voltage read between 220 to 240 volts you are good to go.  Not all outlet combinations will produce the correct voltage so you have to test before each use.  If you push the voltage test button and it reads 120 volts, simply re-located one of the power cords to a different location and retest.  Every job site location has the ability to provide plus or minus 230/240 volts.  If you use 15 amp 115/120 volt circuits then you will only be able to operate 15 amp 230/240 volt equipment.  If your pressure washer needs 23 amps @ 230 volts and you are plugged into 20 amp 115 volt outlets, you will need to turn the pressure down to lower the amp draw.  Just turn the pressure regulator / unloader knob counter clockwise.  The less pressure, the less horsepower is needed to turn the electric motor and this will lower the amp draw.  On welders you will have to turn down the heat too.
Until both 120 volt power cords are connected to a 120 volt electrical source, it is electrically isolated from the electrical circuit of the male plug on the 2nd power cord.  This protects the user from accidental shock through the exposed male plug contact.

Works with the following Zencar Level 2 EV Charger(240V,16A,28ft) Portable EVSE Home Electric Vehicle Charging Station Compatible with Chevy Volt, Nissan Leaf, Fiat, Ford Fusion.

MUSTART MU-P Level 2 Portable EV Charger (25ft Cable, 7.68KW), Electric Vehicle Charger Plug-In EV Charging Station with NEMA 6-50P (32 Amp).
Other 220 to 240 volt receptacles available including but not limited to: NEMA 6-30R, NEMA 6-50R, NEMA 10-30R, 14-30R, 14-50R, and more.

Specification

Plastic Box is 6" X 6" X 5"
Dual 12-3 X 25 ft power cords with dual 20 amp push breakers.
Green Light Voltage Notification
Rubber feet on bottom of box

Video






Additional Information

You must test both wall outlets with a receptacle polarity tester before use!
Electrical Outlet Receptacle Tester 3 wire 120 volt  20100823 Electrical Outlet Receptacle Tester 3 wire 120 volt
Note: User assumes all responsibility on use.  Welder power supply 240 volt outlet converter
It is the users responsibility to check the inbound voltage, outbound voltage, and total amp draw to verify these are not going to be overloaded.  The user agrees to test the amp draw of any appliance or machine that they plug into these converters to ensure they are not being overloaded. Meters are cheap and mistakes are expensive.  You can purchase a meter at
https://www.steam-brite.com/voltage-meter-mulitester-p-6259.html
User agrees to hold Steam Brite, its employees, and agents harmless in the event of any use of said use of converter.  The user agrees to not hold SteamBrite and all employee against any problems that arise out of the use of said converters/ inverters.  Remember, just because it plugs in does not mean it is OK to use!

Please remember the 80/20 electrical rule.  If you are going to plug into a 15 amp outlet and draw long term the device needs to be under 80% of 15 amps = 12 amps max.
If I plug into dual 20 amp breakers long term then the 80/20 rules math is 20 amps X 80% = 16 amps max.  

The
Telsa Electric Cars use 14-50R outlets.

Manufacture 1 Yr warranty.  Add optional 2 or 4 more years for a little more.
Owners Manual

Tips:  One customer wrote, "I plugged into different walls, not the same outlet, and it did not work."

Answer:  This is incorrect step / understanding. understanding left phase vs right phase in a breaker panel

In order to have the power supply box work, it must be plugged into different phases.

There are two phases of power in every home.

Half of all the outlets are on left phase, and the other half is on right phase.

You must land on one of each phase in order for the power supply to work.

This means if I just randomly select two outlets in a home, I could be plugged into:  two left side phases, 2 right side phases, or 1 of left + 1 right (correct use of power supply, depress phase locator button on the power supply box and will illuminate bright green on the phase locator light if you plugged in correctly.)

If you look at the breaker panel (photo to the right) and notice the column of breakers on the left side and then a column on the ride side.

The way a breaker box is wired is the top left breaker is left phase, the 2nd from the top left strait down the left column is right phase, 3rd down is left column is left phase, 4th down is right phase.  These breakers alternate phase location all the way down each column.

The top right column of breakers works exactly the same way.  You have to land on one left phase and and one right phase to make this item work.  It is OK to have landed on a pair of outlets that is left and right side and each is positioned anywhere in the breaker panel.

Since this power supply box will not work with GFCI or LCI outlets you can also replace a GFCI outlet with a standard wall receptacle.  

Optionally, if the two breakers you want to use are on the same phase, simply change the location of one of the two breakers to be in a different position in the column.   This is very easy to do and only takes a screw driver (see video link below.)  Go outside and turn off the breaker and turn off the breaker that is labeled as ‘main.’  Go back to the garage and take off the garage panel cover.  Grab the breaker you want to relocate and simply switch positions with another breaker either one up or one down in the column.   You can change the location of the breaker or change the location of the wire in the breaker (your choice.)  This will put the breaker on a different phase.  Again, see video below on how to do this.

https://youtu.be/BG9I-PokSdI?si=m06267ZWR54Tiknu

and
https://youtu.be/IzTV9t7bnH8?si=p1lgRxxO5gsEvmub

Once you are on different phases, and press the momentary phase location button on your power supply box, the green light will be bright green telling you, you selected one left and one right phase and you are good to use this power supply box below the required amp draw of the wall outlets you plugged into.

Testimonials:
Used regularly by customers of https://www.binzel-abicor.com

Optional Factory Installed 600 Volt, 80,000 Amp Surge Protection

 Square D HEPD80 Whole Home Electronics Protective Device, AC Surge Protection, Type 1 SPD, 120/240VAC, 1Phase 3Wire, 80kA 
 Square D HEPD80 Whole Home Electronics Protective Device, AC Surge Protection, Type 1 SPD, 120/240VAC, 1Phase 3Wire, 80kA 
HEPD devices protect and provide surge suppression for important items that are not compatible with plug strips such as electric cars, concrete grinders, concrete compression testing equipment, floor sanders, concrete dust and HEPA vacuums, laser and light show equipment, table saws, washers, dryers, refrigerators, stoves, heating and air conditioning equipment, and lighting.






Carpet Cleaning Equipment Truckmount Truck Mount Truckmounted Extractor

Steambrite processes shipments daily by Fedex, UPS, and USPS (for small packages), as well as a using a variety of freight carriers for oversized/palletized shipments. While the Steambrite website DOES reflect what is available for purchase, it does NOT reflect available inventory at our local warehouse (San Antonio, TX). Special order, or custom build items may take up to 30 days to arrive, but orders shipped from within Steambrite's warehouse inventory are generally processed and shipped in 2-5 business days. Equipment small enough to be sent by ground should typically arrive within 3-5 business days after shipment. Oversized shipments could take in excess of 6-8 working days to arrive after shipment, and ground shipping times are not guaranteed.
Clean Storm Reverse6-50R Power Joiner Step Up Inverter Dual 20 amp 120 volt outlets To 240 volt 3 wire 20amp 6-50R [Reverse6-50R]

Click here for our full shipping policy. Specifications are subject to change without notice.
Steam Brite Inc shall have no obligation or liability to buyer whether arising in contract (including warranty) tart (including active, passive or imputed negligence) other otherwise for loss of use, revenue or profit, or any other incidental or consequential damages with respect to any non-conformance or defect in any items provided here under. Display images are for reference only, note that all purchases are fulfilled by the part number ordered. You our customer agrees to indemnify Steam Brite Inc and to hold it harmless from and against any and all claims, cost, liabilities, damages and expenses, including attorney's fees, resulting from personal injury or property damaged caused by the Products.
Warranty Disclaimer: Buyer's sole and exclusive remedy for defects in the products shall be as provided in the manufactures's warranty and any other rights provided by law against the manufacturer. Steam Brite, Inc makes no other than as specified in this agreement. All other warranties, express or implied, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose, are hereby disclaimed.




This product was added to our store on Friday 11 October, 2013.
Reviews
Product Datasheet Click on the Acrobat Symbol to download this page as a PDF Document
Related Items:
Power Joiner Step Up Inverter Pressure Washer Converts Dual 20 amp 120 Volt outlets to 240 Volt 3 wire 6-30R Reverse6-30R

Power Joiner Step Up Inverter Pressure Washer Converts Dual 20 amp 120 Volt outlets to 240 Volt 3 wire 6-30R Reverse6-30R (Reverse6-30R)
Power Joiner Step Up Inverter Converts Dual 20 amp 120 Volt outlets to 240 Volt 3 wire 15 amp L6-30R ReverseL6-30R

Power Joiner Step Up Inverter Converts Dual 20 amp 120 Volt outlets to 240 Volt 3 wire 15 amp L6-30R ReverseL6-30R (ReverseL6-30R)
Extension Power Cord 14-3 X 25 feet Heavy duty Lighted Ends Mytee E532 [201100812] D17333025 GTIN 661899107029

Extension Power Cord 14-3 X 25 feet Heavy duty Lighted Ends Mytee E532 [201100812] D17333025 GTIN 661899107029 (201100812)
Clean Storm Reverse14-30R Power Joiner Step Up Inverter Converts Dual 20Amp 115V Outlets to 230V 4 wire Level 2

Clean Storm Reverse14-30R Power Joiner Step Up Inverter Converts Dual 20Amp 115V Outlets to 230V 4 wire Level 2 (Reverse14-30R)
Clean Storm Reverse6-20R Power Joiner Step Up Inverter Electric AC  Dual 20A 120V To 240V 3 Wire GTIN 653341065544

Clean Storm Reverse6-20R Power Joiner Step Up Inverter Electric AC Dual 20A 120V To 240V 3 Wire GTIN 653341065544 (Reverse6-20R)
Clean Storm Reverse10-30R Power Joiner Step Up Inverter Converts Dual 20 amp 115 Volt outlets to allow 230 Volt 3 wire

Clean Storm Reverse10-30R Power Joiner Step Up Inverter Converts Dual 20 amp 115 Volt outlets to allow 230 Volt 3 wire (Reverse10-30R)

Customers who bought this also bought:
Duosida 20180813 Electric Vehicle Charger EVSE 220-240v 16amp Level 2 Nema 6-50P Plug To J1772 Freight Included
Duosida 20180813 Electric Vehicle Charger EVSE 220-240v 16amp Level 2 Nema 6-50P Plug To J1772 Freight Included
Shopping Cart Carpet Cleaning Equipment
0 items
Manufacturer Info
Clean Storm
Other products
Notifications Carpet Cleaning Equipment
NotificationsNotify me of updates to Clean Storm Reverse6-50R Power Joiner Step Up Inverter Dual 20 amp 120 volt outlets To 240 volt 3 wire 20amp 6-50R
Specials Carpet Cleaning Equipment
Husqvarna 967977406 HTC T5 PG540 Duratiq 5 Concrete Grinder Vacuum A2000 HEPA 12947485 805544251907
Husqvarna 967977406 HTC T5 PG540 Duratiq 5 Concrete Grinder Vacuum A2000 HEPA 12947485 805544251907
$20,056.64
$17,056.64
What's New? Carpet Cleaning Equipment
AR Pump XWAM7G40N-SX Pump: 7/4000 1750RPM
AR Pump XWAM7G40N-SX Pump: 7/4000 1750RPM



carpet cleaning equipment
Click here to Apply Online!

Videos

Microban Botaniclean Thymol Disinfectant

Accepted Credit Cards & Paypal
1982 - 2024 Steambrite Supply
Carpet Cleaning Machines|Truck Mount Machines

Quantity1+2+ 4+ 8+ 
Price for each$366.02$354.62$347.92$344.65
Your savings- 3%5%6%